Monthly Archives: September 2012

Troubleshooting Heating – Older Sunline Units

Continuing with my series on troubleshooting packaged units prior to the introduction of Simplicity Controls with diagnostic flash codes, the older Sunline units used a Johnson G67, G770, and/or G775 ignition control.  There were no diagnostic flash codes or lights on this control … Continue reading

Posted in HVAC Tech Support | 16 Comments

ECM Motor Troubleshooting — Part 3

In my last 2 posts, we discussed how to use your meters to check out ECM motors, modules, and control boards.  These checks involved taking voltage reading and resistance reading on the various components to see where the problem occurred … Continue reading

Posted in HVAC Tech Support | 11 Comments

ECM Motor Troubleshooting — Part 2

In my previous post, we covered checking the power and communication to the ECM motor/module.  If all of that was correct, now we need to see if the problem is in the motor, or in the module. Motor Tests These tests … Continue reading

Posted in HVAC Tech Support | 3 Comments

ECM Motor Troubleshooting – Part 1

If you read my last post on “What is an ECM Motor?” you should have a basic understanding of how an ECM motor works.  As promised, we will now talk about how to troubleshoot equipment with ECM motors.  This will … Continue reading

Posted in HVAC Tech Support | 36 Comments

What is an ECM Motor?

Today’s higher efficiency equipment, both furnaces and A/C, are now using new higher efficiency motors to reduce the total electrical consumption of the system thus raising the efficiency. They also help with the efficiency by maintaining the proper air flow (CFM) … Continue reading

Posted in HVAC Tech Support | 31 Comments

Furnace Efficiency?

Meteorological Autumn is here and calendar Autumn starts in just 14 more days. Where has this summer gone?  I know some are very happy to see it go! Now this does not mean A/C season is over but, it is … Continue reading

Posted in Commentary | 2 Comments

Disclaimer

As my profile states, I am employed by Johnson Controls York UPG. I need to make it very clear that the contents of this blog are my own opinions, thoughts, experiences and should not be construed as those of Johnson … Continue reading

Posted in Commentary | 2 Comments